Thermal Stability Test Apparatus
-
To measure/check Thermal stability of PVC
Insulation & Sheath of Electric Cables
as per IS: 5831 & IS: 10810 and heated
in a temp. Controlled chamber. - Measures Thermal Stability time in minutes required to change the pH value of 5 to 3 of a Universal Indicating pH paper placed in a glass tube containing sample & heated in a temp. Controlled heating chamber at specified temp. Of 200°C to ± 0.5°C.
- New model incorporates a specially designed Heating Block which eliminates use of expensive silicone oil as in a conventional model.